11 research outputs found

    Determination of sodium fatty acid in soap Formulation Using Fourier Transform Infrared (FTIR) spectroscopy and multivariate calibrations.

    Get PDF
    Fourier Transform Infrared (FTIR) spectroscopy using an attenuated total reflectance (ATR) accessory has been investigated as a method for the determination of sodium-fatty acid (sodium-FA) in soap formulations. Multivariate calibrations namely partial least squares regression (PLS) and principle component regression (PCR) were developed for the prediction of sodium-FA using spectral ranges on the basis of relevant IR absorption bands related to sodium-FA. The sodium-FA content in soap formulations was predicted accurately at wavenumbers of 1,570–1,550 cm−1, which is specific for RCOO− Na+ vibration. The PLS method was found to be a consistently better predictor when both PLS and principal component regression (PCR) analyses were used for quantification of sodium-FA. Furthermore, FTIR spectroscopy can be an alternative technique to American oil Chemist Society methods which use a titrimetric technique because FTIR offers rapid, easy sample preparation and is friendly to the environment

    Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.

    Get PDF
    Rapid Fourier transform infrared (FTIR) spectroscopy combined with attenuated total reflectance (ATR) was applied for quantitative analysis of virgin coconut oil (VCO) in binary mixtures with olive oil (OO) and palm oil (PO). The spectral bands correlated with VCO, OO, PO; blends of VCO and OO; VCO and PO were scanned, interpreted, and identified. Two multivariate calibration methods, partial least square (PLS) and principal component regression (PCR), were used to construct the calibration models that correlate between actual and FTIR-predicted values of VCO contents in the mixtures at the FTIR spectral frequencies of 1,120–1,105 and 965–960 cm−1. The calibration models obtained were cross validated using the “leave one out” method. PLS at these frequencies showed the best calibration model, in terms of the highest coefficient of determination (R 2) and the lowest of root mean standard error of calibration (RMSEC) with R 2 = 0.9992 and RMSEC = 0.756, respectively, for VCO in mixture with OO. Meanwhile, the R 2 and RMSEC values obtained for VCO in mixture with PO were 0.9996 and 0.494, respectively. In general, FTIR spectroscopy serves as a suitable technique for determination of VCO in mixture with the other oils

    Microstructural and Physiological Changes in Plant Cell Induced by Pressure: Their Role on the Availability and Pressure-Temperature Stability of Phytochemicals

    No full text